Thermocouple Extension wire Type EX-FEP/FEP-2×0.6
Description:
1, SUBJECT
This specification covers the requirements for FEP insulated, FEP sheathed
thermocouple extension cable, type EX, 2×1/0.6mm, stranded wire.
2, TECHNICAL FEATURES
A. Conductors:
Stranded thermocouple extension wire
Conductors Size(AWG) | NO.of Strands &Gauge |
22 | 1/0.6mm |
B. Insulation:
Extruded FEP ( 200℃)
Nominal Insulation Thickness | 0.21mm±0.2mm |
Color code
Positive | Color | Negative | Color |
Chromel | Purple | Alumel | Red |
C. Assembly:
Two conductors (positive and negative) parallel construction.
D. Overall Jacket
Extruded FEP ( 200℃)
Nominal Sheath Thickness | 0.25mm±0.2 |
Color code | Purple |
3, DIMENSIONS AND TOLERANCES
Dimensions/tolerances(mm) | 1.65±0.25×2.50±0.25 |
4, CALIBRATION TOLERANCE
Temperature range | Standard tolerance | Special tolerance |
0º to 200ºC | ±2.2℃ or 0.75% | ±1.1℃ or 0.4% |
Thermocouple extension wire type available: KX, JX, TX, EX, NX, RX,SX and other compensating
cable like KCA, KCB and so on.
Besides those wires, we can also produce according to your demand.
Color code
JIS, DIN and others are also available.