KCA-FG/FG-2*4/0.65

Product Description

Thermocouple Extension wire type KCA-FG/FG-2*4/0.65
Description:

1, SUBJECT
Fiberglass braided insulated thermocouple wire, 2×4/0.65mm, stranded wire, standard tolerances
and color cod
e.

2, TECHNICAL FEATURES

A. Conductors:
Stranded thermocouple extension wire


                                           
       Conductors Size(AWG)        NO.of Strands &Gauge  
       22        4/0.65mm
                                           
B. Insulation:
Braided fiberglass (400ºC)

                       
       Nominal Insulation Thickness        0.23 mm±0.2                                
Color code
                                                                   
       Positive        Color            Negative        Color
       Iron        Red        Copper-Nickel        White
                                           
C. Assembly:
Two conductors (positive and negative) parallel construction.

D. Overall Jacket
Braided fiberglass (400ºC)
                                           
       Nominal Insulation Thickness        0.25mm±0.2mm                  
       Color code        Blue or White trace
                       
3, DIMENSIONS AND TOLERANCES
                       
       Dimensions/tolerances(mm)        2.60±0.2×4.2±0.2              
                               
4, CALIBRATION TOLERANCE
                                                       
       Temperature range        Standard tolerance        Special tolerance
       0℃ to 400℃        ±2.2℃ or 0.75%        ±1.1℃ or 0.4%

Thermocouple extension wire type available: KX, JX, TX, EX, NX, RX,SX and other compensating
cable like KCA, KCB and so on
.
Besides those wires, we can also produce according to your demand.

Color code table


JIS, DIN and others are also available.


                                                       


K-CERAMIC FIBER-2*20AWG

K-PFA/PFA-2*20AWG

K-PFA/PFA-2*24AWG

RTD-TEF/SIL-4*7/0.2

RTD-FEP/CUB/SIL-4*7/0.12